PureGuard Wall Mount Heated Getter



PureGuard™ Wall Mount Heated Getter gas purifiers  provide parts-per-billion (ppb) purity for nitrogen, argon, helium and other rare gases. The reactive zirconium alloy metal in our getter purifiers irreversibly remove all oxide, carbide and nitride impurities. And, the Wall Mount purifiers are the only method to remove nitrogen and methane impurities from rare gases. 

The zirconium getter operates on the bulk diffusion principle to provide outstanding capacity to retain impurities. This large capacity provides long lifetimes because it uses the entire getter media, unlike ambient catalytic purifiers which use only the surface area as active removal sites. This capacity to hold more impurities and remove a broader range of impurities makes it an excellent choice when compared to ambient catalytic purifiers.

JM offers both heated getter and regenerable catalytic purifiers so that you can select the best option for your application.  Typical applications include argon purifiers for silicon and photovoltaic thin-film processes, crystal growth, nitrogen purifiers for MOCVD purge gas and nitrogen or argon gas purifiers for calibration gas for analytical instrumentation.

If you need an argon purifier that provides the purest argon with no oyxgen, carbon or nitrogen impurities, then the Wall Mount argon purifiers are the perfect solution.


Learn more about Heated Getter Purifier Technology in our Library

 

PureGuard Wall Mount I and II – 0-75 slpm

The Wall Mount I is our most basic system with the necessary features to provide < 1 ppb outlet purity. Manual inlet & outlet valves are mounted with the purifier vessel on a solid back plate to facilitate easy mounting.

The Wall Mount II purifier adds an enclosure with automatic internal bypass valves and additional alarm capabilities for local and remote monitoring. 

Key Features
Gases purifiedNitrogen, argon, helium and other rare gases
Purity< 1 ppb O2, H2O, CO, CO2, N2, H2, THC
Filtration0.003µm outlet metal filter
Max pressure250 psig
Power120VAC or 220VAC
Pneumatic pressure

80-100 psig (4.8-6.9 bar) min/max  (Wall Mount II only)

  
ModelDescriptionFeaturesGasMax Flow Rate
WMA-I-1000Wall Mount I Heated Getter PurifierManual inlet & outlet valvesArgon, rare gases30 slpm
WMN-I-1000Wall Mount I Heated Getter PurifierManual inlet & outlet valvesNitrogen30 slpm
WMA-I-2000Wall Mount I Heated Getter PurifierManual inlet & outlet valvesArgon, rare gases50 slpm
WMN-I-2000Wall Mount I Heated Getter PurifierManual inlet & outlet valvesNitrogen50 slpm
WMA-II-2000Wall Mount II Heated Getter PurifierAutomatic inlet, outlet & bypassvalve, safety enclosureArgon, rare gases75 slpm
WMN-II-2000
Wall Mount II Heated Getter PurifierManual inlet & outlet valvesvalve, safety enclosureNitrogen75 slpm

Data Sheet: Wall Mount I and II
Pressure Drop Curve: Wall Mount II
Dimensional Drawings: Wall Mount I | Wall Mount II
Technical Articles:

 

PureGuard Wall Mount III – 20-100 slpm

The Wall Mount III purifier offers more features to handle flow rates up to 100 slpm typical of high-production semiconductor and PV fabs or ICP-MS instruments. This purifier includes an auto bypass, flowmeter and PLC with menu-driven display in a compact enclosure.

The purifier also includes a real-time end-of-life monitoring system to provide continuous display of remaining lifetime. The system monitors total gas flow correlated with inlet impurity levels and displays a ‘gas gauge’ type image to alert you when it is time to replace the getter vessel. Other competitive purifier detection methods are not accurate due to channeling and uneven breakthrough of impurities. The End-of-Life monitor from JM gives you confidence that monitoring is continuous and accurate.

Key Features
Gases purifiedNitrogen, argon, helium and other rare gases
Purity< 1 ppb O2, H2O, CO, CO2, N2, H2, THC
Filtration0.003µm outlet metal filter
Max pressureMax pressure: 250 psig
Power120VAC or 220VAC
Pneumatic pressure60-70 psig (4.1-4.8 bar) min/max
OperationPLC with menu-driven display
MountingWall or surface mounting
Wall mount heated getter gas purifer
  
ModelMax FlowGasVoltagePneumatic Pressure
WMA-III-3000100 slpmAr, He, rare gas208-240 VAC 50/60 Hz60-70 psig min/max
WMN-III-3000100 slpmN2208-240 VAC 50/60 Hz60-70 psig min/max

Data Sheet: Wall Mount III
Pressure Drop Curve: Wall Mount III
Dimensional Drawings: Wall Mount III
Technical Articles: